Forward Transformers Similar To P/N 1043
Application:
Table below shows additional 1kW, 150 kHz transformers
designed for the same environment as P/N1043. P/N 1041 and
1042 dimensions are the same as shown above for P/N 1043.
Transformers P/N 1037 through 1040 have different output
tabs because they deliver higher currents. Their mechanicl
drawings are shown below. |
Part No. |
Description |
Input |
Converter Output |
Ratio Np/ Ns |
Frequency |
Efficiency |
Max. Duty Cycle |
P/N
1037 |
P220-16-1 |
180-320 VDC |
3.3VDC
/ 240A |
16
turns/ 1 turn |
100
kHz |
98.30% |
44% at
low line |
P/N 1038 |
P220-12-1 |
180-320
VDC |
5VDC / 180A |
12 turns/ 1 turn |
150 kHz |
98.50% |
38% at
low line |
P/N 1039 |
P220-12-2 |
180-320
VDC |
12VDC / 85A |
12 turns/ 2 turns |
150 kHz |
98.80% |
43% at
low line |
P/N 1040 |
P220-14-3 |
180-320
VDC |
15VDC / 65A |
14 turns/ 3 turns |
150 kHz |
98.60% |
44% at
low line |
P/N 1041 |
P220-12-4 |
180-320
VDC |
24VDC / 42A |
12 turns/ 4 turns |
150 kHz |
98.60% |
44% at
low line |
P/N 1042 |
P220-12-5 |
180-320
VDC |
28VDC / 36A |
12 turns/ 5 turns |
150 kHz |
98.70% |
40% at
low line |
1.0 KW Output P/N 1037, 1038, 1039, 1040

Notes
- Dimensions are in inches
- Drawing not to scale